Model RT-ZD10
Maker R&S
Description Active Differential Probe, 1 GHz
Rental 문의요망
Stock 문의요망
- The R&S RT‑ZD10/20/30 is a differential probe with high input impedance. It is used for differential voltage measurements from DC to 1.0 GHz, 1.5 GHz, and
- 3 GHz, respectively. Differential probes can be used for single-ended and differential applications. They are equipped with two high-impedance inputs and can measure the voltage
- between any two test points. Unlike using single-ended probes, there is no need to ensure that one of the test points is always at ground potential.
- The comprehensive accessory set allows this probe to be connected to a wide variety of devices under test (DUT). Provided with special features such as the
- R&S ProbeMeter and the micro button, the R&S RT‑ZD10/20/30 is designed to meet tomorrow’s challenges in probing.
- The external attenuator R&S RT-ZA15 can be used to extend the input voltage range of the R&S RT‑ZD10/20/30. It is supplied with the R&S RT-ZD10 and is available as optional accessory for the R&S RT-ZD20 and R&S RT-ZD30.
- The probe is equipped with the Rohde & Schwarz probe interface. It can be connected to any Rohde & Schwarz instrument that is compatible with this interface.
- When connected to the front panel, the probe is controlled by the oscilloscope’s software. Supported oscilloscopes are listed in the data sheet.
SPECIFICATIONS
- The key characteristics of the probe are the following:
- Bandwidth DC to 1.0 GHz (R&S RT-ZD10)
- DC to 1.5 GHz (R&S RT-ZD20)
- DC to 3.0 GHz (R&S RT-ZD30)
- Dynamic range
- (differential input)
- ±5 V with ±5 V offset capability
- 10 V AC (Vpp)
- Key features and key characteristics
- R&S®RT‑ZD10/20/30 Product description
- User Manual 1410.4550.02 ─ 06 10
- Operating voltage window
- (each pin to GND)
- ±8 V with ±22 V common mode offset capability
- Available for R&S RT‑ZD10/20/30 probes with serial
- number ≥ 200000
- Maximum non-destructive input voltage ±30 V
- Between each signal pin and ground
- Diff. input resistance 1 MΩ
- Diff. input capacitance 0.6 pF
- R&S ProbeMeter, measurement error <0.1 %
- Extremely low zero and gain errors throughout the entire temperature range, no significant temperature drift
- Micro button
- Rohde & Schwarz probe interface
RT-ZD10 RT-ZD10 R&S R&S RT-ZD10 RT-ZD10 RS RS RT-ZD10 RT-ZD10 ROHDE SCHWARZ ROHDE SCHWARZ RT-ZD10 RT-ZD10 로데슈바르즈 로데슈바르즈 RT-ZD10 RT-ZD10 로데슈바르츠 로데슈바르츠 RT-ZD10 RT-ZD10 중고 중고 RT-ZD10 RT ZD10 RT ZD10 R&S R&S RT ZD10 RT ZD10 RS RS RT ZD10 RT ZD10 ROHDE SCHWARZ ROHDE SCHWARZ RT ZD10 RT ZD10 로데슈바르즈 로데슈바르즈 RT ZD10 RT ZD10 로데슈바르츠 로데슈바르츠 RT ZD10 RT ZD10 중고 중고 RT ZD10
[배송 정책]
저희는 고객 편의를 위해 다양한 배송 옵션을 제공합니다.
기본 배송 안내
- 배송 지역 | 대한민국 전지역
- 배송비 | 4,000원 (100,000원 이상 결제시 무료배송)
- 택배사 : 우체국택배
- 배송기간 | 주말 공휴일 제외 2~5일
- 일부 제품의 경우 본사 또는 파트너사에서 바로 출하되어 택배사가 변경될 수 있습니다.
- 배송은 택배사 사정으로 지연될 수 있으며 정확한 배송 일정은 주문 시점과 지역에 따라 달라질 수 있습니다.
추가 배송 옵션
- 고객 요청 시, 퀵서비스를 이용한 신속 배송이 가능합니다. 퀵서비스 이용 여부 및 비용은 영업팀과 사전 협의를 통해 결정됩니다.
- 고객 요청 시, 화물(경동화물)을 이용한 배송도 가능합니다.
배송 주의 사항
- 장비 발송 후 배송 과정에서 발생하는 문제(예: 배송 지연, 분실 등)에 대한 책임은 당사의 배송 파트너와 협의하여 신속히 해결해 드립니다.
- 수령 후에는 즉시 장비 상태를 확인하시고, 이상이 있을 경우 수령일로부터 24시간 이내에 저희에게 알려주시기 바랍니다.
[교환&환불 정책]
저희 플랫폼은 고가의 계측장비를 전문적으로 판매 및 렌탈하는 특성상 아래의 환불 정책을 적용합니다.
계약 체결 이후 환불 불가
- 구매 또는 렌탈 계약 체결 후에는 고객의 단순 변심이나 사용 의사 변경으로 인한 환불이 불가능합니다.
- 고객은 계약 체결 전에 모든 장비의 상태, 기능 및 조건을 충분히 확인해야 할 책임이 있습니다.
- 초기 불량으로 인한 고장은 환불 대상이오나, 고객의 부주의나 잘못된 사용으로 인한 고장의 경우에는 해당하지 않습니다.
예외 상황 및 책임 한정
- 고객이 장비를 수령하기 전에 주문을 취소한 경우, 렌탈료의 20%를 취소 수수료로 공제하고 나머지를 환불합니다.
- 고객은 장비 사용 중 발생하는 모든 손상, 분실, 또는 오작동에 대해 책임이 있으며, 이로 인해 환불이 제공되지 않습니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
세상에서 가장 상큼한 B2B 중고렌탈 플랫폼 - 🍇포도크림🍦
Model RT-ZD10
Maker R&S
Description Active Differential Probe, 1 GHz
Rental 문의요망
Stock 문의요망
- The R&S RT‑ZD10/20/30 is a differential probe with high input impedance. It is used for differential voltage measurements from DC to 1.0 GHz, 1.5 GHz, and
- 3 GHz, respectively. Differential probes can be used for single-ended and differential applications. They are equipped with two high-impedance inputs and can measure the voltage
- between any two test points. Unlike using single-ended probes, there is no need to ensure that one of the test points is always at ground potential.
- The comprehensive accessory set allows this probe to be connected to a wide variety of devices under test (DUT). Provided with special features such as the
- R&S ProbeMeter and the micro button, the R&S RT‑ZD10/20/30 is designed to meet tomorrow’s challenges in probing.
- The external attenuator R&S RT-ZA15 can be used to extend the input voltage range of the R&S RT‑ZD10/20/30. It is supplied with the R&S RT-ZD10 and is available as optional accessory for the R&S RT-ZD20 and R&S RT-ZD30.
- The probe is equipped with the Rohde & Schwarz probe interface. It can be connected to any Rohde & Schwarz instrument that is compatible with this interface.
- When connected to the front panel, the probe is controlled by the oscilloscope’s software. Supported oscilloscopes are listed in the data sheet.
SPECIFICATIONS
- The key characteristics of the probe are the following:
- Bandwidth DC to 1.0 GHz (R&S RT-ZD10)
- DC to 1.5 GHz (R&S RT-ZD20)
- DC to 3.0 GHz (R&S RT-ZD30)
- Dynamic range
- (differential input)
- ±5 V with ±5 V offset capability
- 10 V AC (Vpp)
- Key features and key characteristics
- R&S®RT‑ZD10/20/30 Product description
- User Manual 1410.4550.02 ─ 06 10
- Operating voltage window
- (each pin to GND)
- ±8 V with ±22 V common mode offset capability
- Available for R&S RT‑ZD10/20/30 probes with serial
- number ≥ 200000
- Maximum non-destructive input voltage ±30 V
- Between each signal pin and ground
- Diff. input resistance 1 MΩ
- Diff. input capacitance 0.6 pF
- R&S ProbeMeter, measurement error <0.1 %
- Extremely low zero and gain errors throughout the entire temperature range, no significant temperature drift
- Micro button
- Rohde & Schwarz probe interface
RT-ZD10 RT-ZD10 R&S R&S RT-ZD10 RT-ZD10 RS RS RT-ZD10 RT-ZD10 ROHDE SCHWARZ ROHDE SCHWARZ RT-ZD10 RT-ZD10 로데슈바르즈 로데슈바르즈 RT-ZD10 RT-ZD10 로데슈바르츠 로데슈바르츠 RT-ZD10 RT-ZD10 중고 중고 RT-ZD10 RT ZD10 RT ZD10 R&S R&S RT ZD10 RT ZD10 RS RS RT ZD10 RT ZD10 ROHDE SCHWARZ ROHDE SCHWARZ RT ZD10 RT ZD10 로데슈바르즈 로데슈바르즈 RT ZD10 RT ZD10 로데슈바르츠 로데슈바르츠 RT ZD10 RT ZD10 중고 중고 RT ZD10
[배송 정책]
저희는 고객 편의를 위해 다양한 배송 옵션을 제공합니다.
기본 배송 안내
- 배송 지역 | 대한민국 전지역
- 배송비 | 4,000원 (100,000원 이상 결제시 무료배송)
- 택배사 : 우체국택배
- 배송기간 | 주말 공휴일 제외 2~5일
- 일부 제품의 경우 본사 또는 파트너사에서 바로 출하되어 택배사가 변경될 수 있습니다.
- 배송은 택배사 사정으로 지연될 수 있으며 정확한 배송 일정은 주문 시점과 지역에 따라 달라질 수 있습니다.
추가 배송 옵션
- 고객 요청 시, 퀵서비스를 이용한 신속 배송이 가능합니다. 퀵서비스 이용 여부 및 비용은 영업팀과 사전 협의를 통해 결정됩니다.
- 고객 요청 시, 화물(경동화물)을 이용한 배송도 가능합니다.
배송 주의 사항
- 장비 발송 후 배송 과정에서 발생하는 문제(예: 배송 지연, 분실 등)에 대한 책임은 당사의 배송 파트너와 협의하여 신속히 해결해 드립니다.
- 수령 후에는 즉시 장비 상태를 확인하시고, 이상이 있을 경우 수령일로부터 24시간 이내에 저희에게 알려주시기 바랍니다.
[교환&환불 정책]
저희 플랫폼은 고가의 계측장비를 전문적으로 판매 및 렌탈하는 특성상 아래의 환불 정책을 적용합니다.
계약 체결 이후 환불 불가
- 구매 또는 렌탈 계약 체결 후에는 고객의 단순 변심이나 사용 의사 변경으로 인한 환불이 불가능합니다.
- 고객은 계약 체결 전에 모든 장비의 상태, 기능 및 조건을 충분히 확인해야 할 책임이 있습니다.
- 초기 불량으로 인한 고장은 환불 대상이오나, 고객의 부주의나 잘못된 사용으로 인한 고장의 경우에는 해당하지 않습니다.
예외 상황 및 책임 한정
- 고객이 장비를 수령하기 전에 주문을 취소한 경우, 렌탈료의 20%를 취소 수수료로 공제하고 나머지를 환불합니다.
- 고객은 장비 사용 중 발생하는 모든 손상, 분실, 또는 오작동에 대해 책임이 있으며, 이로 인해 환불이 제공되지 않습니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
세상에서 가장 상큼한 B2B 중고렌탈 플랫폼 - 🍇포도크림🍦